home page

LimassolInstallation of combined cold storageResearch on assembly process method

2024-03-25 01:10:35release

LimassolHow to install the cold storage unit,

There are many kinds of cold storage. According to the material, it can be divided into color steel plate, color steel plate has strong anti rust ability but stainless steel plate has strong anti rust ability, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is .mm and mm, without color requirements; The thickness of salted steel plate is .mm, without color requirements; The thickness of PE paint baking board is .mm, .mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm, and the thickness of the vertical plate is mm and mm, which is suitable for the insulation conditions of - ℃ ~ - ℃; mm storage plate: the thickness of the ceiling plate is mm and the thickness of the vertical plate is mm, which is suitable for the thermal insulation conditions of ℃ ~ - ℃. The thickness of the ceiling plate and the vertical plate of mm storage plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = mm, heaven and earth plate width WB = mm, vertical angle plate W = mm, W = mm, W = mm and W = . The dimensions of non-standard plates are different from those of Wa, WB and W.Cold storage is fireproof, flame retardant and high resistance. Professional cold storage installation, cold storage installation, medical cold storage and other special products fruit preservation cold storage, old brands, price advantages and guaranteed quality. Polyurethane is a flame retardant self extinguishing material after adding flame retardant. Its softening point can be above degrees Celsius and will only be decomposed at higher temperatures. In addition, the ash formed on the surface of polyurethane will be in its foam, and this ash will help isolate the foam below. It can effectively prevent the spread of fire. Moreover, polyurethane will not produce harmful gas at high temperature.LimassolThe valve shall be installed as close as possible to the cooling fan. The solenoid valve shall be installed horizontally, the valve body shall be vertical, and pay attention to the liquid outlet direction.The ultrasonic town is a patented technology with a shaped energy cover which increases the effective humidification amount by -% per hour. What are the reasonable aspects of the design of the quick freezing warehouse?Kota,We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home, still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage quality assurance. During the preferential activities, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse and the penetration of the envelope is carried out from outside to inside all year round. R gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, it is effective to seal the hot side of the insulation layer, that is,LimassolRequirements for pharmaceutical cold storage, to form a vapor barrier layer.For the ground insulation of large cold storage, we can that the ground insulation of medium-sized cold storage is more complex than that of small cold storage, and the ground insulation operation of large cold storage with larger warehouse area will be more complex. The common operations are as follows: first lay the ventilation pipe to prevent the ground from freezing drum cracking, then lay the XPS extruded plate (staggered laying is required when laying the extruded plate), then lay the moisture-proof and vapor barrier on the upper and lower sides of the extruded plate, then pour the reinforced concrete (generally at least cm thick), and then make the emery floor or epoxy floor according to the requirements. Among them, the XPS extruded plate is also laid according to the warehouse temperature. For example, the XPS extruded plate with thickness of ~ mm needs to be laid in the general low-temperature cold storage, while the XPS extruded plate with thickness of ~ mm can be laid in the high-temperature cold storage.There should be excellent drainage pipe standard around the warehouse, the soil temperature should be low,LimassolProfessional installation of cold storage, there should be interlayer under the cold storage, and maintain good natural ventilation. Maintaining dryness is very important for the cold storage. In addition, the phase electricity of the relative volume shall be built according to the output power of the refrigeration unit. If the cold storage is water-cooled and radiating, the tap water pipeline shall be paved and the FRP cooling tower shall be built.


LimassolInstallation of combined cold storageResearch on assembly process method



Before the acceptance and delivery of the project, the board surface shall be wiped clean. If there is any scratch, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.High value,Compression refrigerator is commonly used. It is mainly composed of compressor, condenser, throttle valve and evaporation pipe. The evaporation pipe is installed in the refrigeration warehouse. When the liquid coolant passes through the evaporation pipe, it directly absorbs the heat in the warehouse and cools down.During the early operation of the refrigeration unit, carefully observe the oil return of the compressor and keep it clean. If it is found that the oil level is not clean enough or the oil level drops, replace it with new oil in time, so as to avoid bad compressor and reduce the service life of the compressor.Install the library body. Generally, the warehouse body can be divided into small warehouse body and large warehouse body. The small warehouse body is basically a combined cold storage assembled with warehouse plate. The large warehouse body is mostly a civil cold storage. The assembled or constructed warehouse body is generally required to be flat, compact and solid, without hollow feeling, load-bearing, antifreeze, moisture-proof etc.


LimassolInstallation of combined cold storageResearch on assembly process method



When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of mm and mm outside.Application process,In order to ensure the safety of construction and cold storage operation, the span between the top storage plate supports (lifting points) shall comply with the following provisions: the polystyrene top storage plate (mm thick) has a very large span of M, and the polyurethane top storage plate (mm thick) has a span of m.The shelves in the warehouse shall have sufficient strength and rigidity.The importance of regular oil discharge, descaling and air discharge in the refrigeration system of the warehouse.Limassol,Points of multi-storey cold storage: small, which can save land; When the storage capacity is the same, the surface area of the outer enclosure structure is smaller than that of the single-layer cold storage, so that the cold consumption can be reduced, the dry consumption of food can be reduced, and the machinery and equipment cost and operation and management cost can be reduced accordingly. At the same time, due to the saving of thermal insulation materials, the civil construction cost per unit area is low and the investment cost is small; The multi-storey location can be reasonable, such as the cooling room can be used as the cold storage room, the attic on the top floor can be built into the ice making room, etc.Features of quick freezing warehouse: the quick freezing technology is advanced, the frost free quick freezing method is adopted, the famous brand compressor and refrigeration accessories are configured, and the automatic frost is adopted. The method can only be used by microcomputer. The refrigeration system adopts green refrigerant, which belongs to the international advanced refrigeration technology in the st century.The service life of the cold storage depends on the quality of the refrigeration equipment, but it also has a great relationship with the proper daily management and maintenance after the installation of the cold storage. Many times, people often ignore the latter point. In daily life, as long as we maintain and maintain the cold storage regularly, we can greatly improve the service life of the cold storage and reduce the cost.

label:
5answers
plumbing equipm
2floor-- · 2024-03-25 08:17:52

LimassolInstallation of combined cold storage The delivery is fast and the quality is good, but the logistics is a bit slow. Overall it is good, continue to support!

See more
Tuoyi Electroni
3floor-- · 2024-03-25 09:23:58

Great LimassolInstallation of combined cold storage, very good service, thank you.

See more
Shencheng Engin
4floor-- · 2024-03-25 09:46:13

Do you have LimassolInstallation of combined cold storage here? LimassolInstallation of combined cold storageWhat is the spot price

See more
Yali Fashion Ap
5floor-- · 2024-03-25 09:57:57

In anticipation, I finally waited for my beloved LimassolInstallation of combined cold storage, I wish the boss a prosperous business and wealth!

See more
Hengsheng Tile
6floor-- · 2024-03-25 10:04:39

Although LimassolInstallation of combined cold storage has not yet arrived, I am looking forward to it, and the inquiry is still in transit.

See more
Sign in Post answer
Related issues
view all
Collectors(1)