home page

JiusamoMedical freezingHow to install and operate reasonably

2024-04-11 02:57:22release

Moreover, polyurethane does not produce harmful gas at high temperature.Floor insulation of small cold storage the structure of small cold storage is usually called surface, that is, the top wall and ground are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, because the loading and unloading of small cold storage is often handled manually rather than forklift. Of course, loading and unloading, but the ground needs to be insulated separately like the ground insulation sample of medium-sized cold storage.Jiusamo,There are several types of insulation materials. One is to produce and process plates with fixed shape and specification, fixed length, total width and thickness. Plates of corresponding specifications and models can be selected according to the installation of the refrigerator body. High and medium temperature refrigerators generally use cm thick refrigerator plates, and ultra-low temperature refrigerators and freeze-cleaning refrigerators generally use cm or cm thick refrigerator plates; Another kind of sprayed polyurethane foam can be sprayed immediately into the finished brick or concrete warehouse. After forming, it is both waterproof and thermal insulation. Thermal insulation materials include polyurethane, polystyrene grease, etc. polyurethane is non hygroscopic and has good fire resistance, but the cost is high; Polystyrene resin has strong water absorption and poor fire resistance,JiusamoLibrary installation, but the cost is low. The structure of modern cold storage is developing in the direction of dress matching architecture. They are made into prefabricated components including steam barriers and heat shields to ensure field assembly. Its advantage is that the project construction is convenient, fast and movable, but the project cost is relatively high.Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.El Cerrito,Compression refrigerator is commonly used, which is mainly composed of compressor, condenser, throttle valve and evaporation pipe. According to the way of evaporation pipe device, it can be divided into direct cooling and indirect cooling. Direct cooling the evaporation pipe is installed in the refrigerated warehouse. When the liquid coolant passes through the evaporation pipe, it will directly absorb the heat in the warehouse and cool down.There are many application scenarios of cold storage, which are different. For a long time, it provides various cold storage installation, cold storage installation,JiusamoInstallation price of small cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, on-site settlement, honest operation, and has offices all over the country for long-term cooperation. Different purposes,JiusamoInstallation price of small cold storage, functions and designs, so what needs to be understood in cold storage design?Cold storage design steps: selection and preparation of cold storage location. According to the application characteristics, cold storage can be divided into sexual cold storage, retail cold storage and large-scale cold storage. When large-scale cold storage starts to build a planting area with more centralized hand supply, factors such as superior geographical location and contact with the market should also be taken into account. The cold storage should be located in a cool place without sunlight and frequent warm air. Small and medium-sized cold storage should be built in the room. cold storage


JiusamoMedical freezingHow to install and operate reasonably



The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with . color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove, and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation and the rivet spacing in the warehouse should be mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.After evacuation, fill the refrigerant into the liquid storage to % of the standard filling volume & mdash; % by weight, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.Safety production,Cold storage design steps: selection and preparation of cold storage location. According to the application characteristics, cold storage can be divided into sexual cold storage, retail cold storage and large-scale cold storage. When large-scale cold storage starts to build a planting area with more centralized hand supply, factors such as superior geographical location and contact with the market should also be taken into account. The cold storage should be located in a cool place without sunlight and frequent warm air. Small and medium-sized cold storage should be built in the room. cold storageCompression refrigerator is commonly used. It is mainly composed of compressor, condenser, throttle valve and evaporation pipe. The evaporation pipe is installed in the refrigeration warehouse. When the liquid coolant passes through the evaporation pipe, it directly absorbs the heat in the warehouse and cools down.Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron and tighten it horizontally, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.


JiusamoMedical freezingHow to install and operate reasonably



The exhaust temperature of the compressor equipment is often. When the season changes and the temperature difference changes greatly, pay attention to it. If the machine is abnormal, it needs to be checked in time.Analysis project,Insufficient refrigeration dose and capacity in the system: there are two main reasons for insufficient refrigerant circulation,Wires should not be in the open air to avoid long-term sun exposure and wind blowing, wire skin aging, long-term cold storage installation, installation of cold storage cold storage construction, fruit preservation cold storage, so as to avoid price difference, and the price is % higher than the market price! The price of more than one ton is higher! Short circuit, leakage, etc.The refrigerator compressor unit generally adopts high-end units with guaranteed quality and strong operation stability. The evaporator adopts the imported joint venture refrigeration air-cooled evaporator, which can effectively meet the refrigeration capacity of the refrigerator and ensure the refrigeration effect of the refrigerator. The refrigerator lamp adopts the special LED energy-saving lamp for the refrigerator, which has the advantages of low temperature resistance, low energy consumption and long service time, It can effectively save the operation cost of cold storage.Jiusamo,When using the cold storage, try to keep the ground clean and professional cold storage installation,The three-dimensional automatic cold storage adopts a computer, unloading and stacking in the storage, the control of storage temperature and the operation of refrigeration equipment.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.

label:
3answers
Sichuan Mustard
2floor-- · 2024-04-11 10:09:11

I'm busy, I forgot, I'm sorry, what else can I say~~ This JiusamoMedical freezing is really good, lucky enough.

See more
Quanzhong Tradi
3floor-- · 2024-04-11 10:14:29

JiusamoMedical freezing It’s good, the price is right, friends also say it’s good, it’s worth it

See more
Janssen Wood Pr
4floor-- · 2024-04-11 11:13:13

Thank you faithfully, let me buy the dream JiusamoMedical freezing, thank you so much!

See more
Sign in Post answer
Related issues
view all
Collectors(1)